1.Energized and self-lubricated strips
Less friction between piston and cylinder
It prevents the bonding of the seal to the cylinder even after long periods of inactivity

2.Slots, bushes and pins made by steel with hardness higher than 50 HRC
Higher resistance to the forces inside the actuator

3.Rolling friction between piston and slot
Less friction

4.Scotch yoke with rolling friction (transforming rotary motion into linear motion using piston and shaft without teeths/gears)
Reduced friction between piston and shaft with consequently less wear on the relevant parts
Empowered Breakaway Torque (BTO & BTC)
Smaller volume/size than rack and pinion actuators (with the same torque) therefore less space required for installation
Less weight than the rack and pinion (-30% kg / Nm), with consequent savings on the construction sizing of the plant/equipment
Lower air consumption compared to the rack and pinion actuators (-40% air cm3/Nm for Double Acting and -20% air cm3/Nm for Spring Return) therefore less load on the compressor or the possibility of using a smaller compressor's size.

5.Rolled cylinder

Less wear of the energized ties thanks to the low roughness of the surface

6.Stainless steel shaft
Higher corrosion resistance

From sizes bigger than GD15, NAMUR interface for solenoid valve is already integrated.
No need for extra plate.

100% in- house manufacturing process technology
Maximum control and accuracy in all the stages of the manufacturing process

ATEX Certificate
Installation is allowed in a potential explosive environment

Up to SIL 3 Certified
Guarantee of the high level of functional safety.

TECHNICAL FEATURES
Torque from 720 Nm to 1920 Nm
Mounting flange according to EN ISO 5211
F10 - F12 - F14 - F16
In compliance with EN 15714-3
Rotation angle 92° (-1° +91°)
Torque: directly proportional to the air supply (see table pneumatic actuator GD)
In the code of standard version GD actuators, it is indicated the breakaway torque in Nm at 5,6 bar air supply.
Actuator with epoxy painting
ATEX version in conformity with directive 2014/34/EU

WORKING CONDITION
Temperature: from -20°C to +80°C
Air supply: 5,6 bar; maximum 8,4 bar
Actuating media: filtered dry compressed air, not necessarily lubricated. In case of lubricated air, either non detergent oil, NBR compatible oil, must be used.

 DATA SHEET
Code
GDC0720416S
GDC0960416S
GDC1440424S
GDC1440416S
GDC1920416S
Spare seals
KGGSS123
KGGSS124
KGGSS125
KGGSS125
KGGSS126
Size
GD0720
F10/F12
GD0960
F12/F16
GD1440
F12
GD1440
F14
GD1920
F12/F16
A
401,5
441
524,8
524,8
562
B
27
36
36
36
46
C x depth
M10x11,5
M12x20
M12x18
M16x18
M12x23
D x depth
M12x11,5
M20x20
-
-
M20x23
ØE
102
125
125
140
125
ØF
125
165
-
-
165
G
19,5
19,5
19,5
19,5
18,5
ØH
156
169
188
188
211
I
22
24
27
27
32
J
138,5
156,3
179,5
179,5
192
K
115
150
130
130
150
L
178
198
216
216
237,7
M
78,5
93,5
101,5
101,5
114,7
N
99,5
104,5
114,5
114,5
123
O
29,5
38,5
38,5
38,5
48,5
P
116
135
160
160
160
ØR
31,8
36,5
41
41
46
S
30
30
30
30
30
T
148
168
186
186
207,7
X
150
150
150
150
150
Y
155
168
187
187
209
Z
345,8
381
433,8
433,8
469
Ch
24
24
30
30
30
Weight  (Kg)
30
40
50,5
50,5
73
Air (dm³/cycle) (l/cycle)
3,7
4,8
7,7
7,7
10

GD PNEUMATIC ACTUATOR OPERATING DIAGRAM